New Chandler-Krack 60 HP Low Temp System, 3 Phase 460 Volt

60 HP outdoor refrigeration system with two high-profile electric defrost evaporators for walk-in/drive-in freezer applications

The Chandler-Krack 60 HP low-temperature refrigeration system pairs a Chandler outdoor air-cooled condensing unit with two Krack high-profile electric defrost evaporators. Designed for operation on R-449A, this system is sized for a -6°F room temperature at -15°F saturated suction temperature (SST) and +95°F ambient.

Condensing Unit

·         1- New 60 HP Chandler outdoor, air-cooled condensing unit.

·         Unit model: HCD0600LDACD with Copeland Discus compressors.

·         460 volt, 3 phase, R-449A, AWEF #N/A.

·         Approx dim: 171”D x 93”L x 56”H, net wgt: Ibs.

·         Two piping circuits.

·         Options included: Replaceable core suction filter and pressure fan cycling.

·         Rating: 249,440 BTUH @ -15° SST/+95° ambient.

Evaporator

·         2 – New Krack high profile evaporators.

·         Model: SMA34E-1393RCMM, electric defrost, 27,400 CFM.

·         3 - 30” fans, 460 volt, 3 phase, AWEF #N/A.

·         Options included: Mounted R-449A TXV and solenoid.

·         Approx dim: 39”D x 135”L x 51”H, ship wgt:  Ibs.

·         Rating: 140,175 BTUH @ 10° T.D/R-449A.

System Notes

·         Sized for -6°F room temperature, -15° SST, and +95°F ambient using R-449A.

·         Defrost timer and fan/heater contactor are not included

 

Get it right. Call our knowledgeable US-based sales staff for assistance at (888) 661-0871.


Description
New 60 HP Chandler-Krack Low Temp System, 3 phase 460 volt
Hot Deals
Yes
Dimensions
Condensing Unit: 171”D x 93”L x 56”H; Evaporator: 39”D x 135”L x 51”H
BTUH Capacity
Condensing Unit: 249,440 BTUH @ -15° SST/+95° ambient; Evaporator: 140,175 BTUH @ 10° T.D/R-449A
Manufacturer
Condensing Unit: Chandler; Evaporator: Krack
Model #
Condensing Unit: HCD0600LDACD; Evaporator: SMA34E-1393RCMM
Defrost
Electric Defrost
Phase - Voltage
3 phase 460 volt
Warranty
New units include factory warranty
Application / Temperature
Low Temp
Horsepower (HP)
60 HP
Refrigerant Class
A1
Item Condition
New